40G QSFP+ SR4

40G QSFP+ SR4 光纖模組
Hot Pluggable, MPO / MTP, 850nm VCSEL, Multi-Mode, OM3 for 100M / OM4 for 150M

詢價單 規格 應用 特點 下載
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I9-M85-X1D40G850nmMPO/MTPOM3 100mOM4 150m0~70°CQSFP+ 40G-SR4FQFP-I9-M85-X1Di40G850nmMPO/MTPOM3 100mOM4 150m-40~85°CQSFP+ 40G-SR4, I-Temp 40Gb EthernetOTN OTU3 @43.01G, OTU3e2 @44.58GBreakout to 4 x 10GBASE-SR EthernetInfiniBand QDR interconnectsData Center & StorageDatacom / Telecom Switch & Router Compliant with IEEE802.3ba 40GBASE-SR4Compliant with SFF-8436 QSFP+ MSASupport InfiniBand QDR4 independent full-duplex channelsUp to 11.2Gbps data rate per channelHot Pluggable850nm VCSEL array transmitterMPO-12 receptacle connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 100m over MM OM3 fiber and 150m over MM OM4 fiberRoHS Compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I9-M85-X3D40G850nmMPO/MTPOM3 300mOM4 400m0~70°CQSFP+ 40G-eSR4 40Gb EthernetOTN OTU3 @43.01G, OTU3e2 @44.58GBreakout to 4 x 10GBASE-SR EthernetInfiniBand QDR interconnectsData Center & StorageDatacom / Telecom Switch & Router Compliant with IEEE802.3ba 40GBASE-SR4Compliant with SFF-8436 QSFP+ MSASupport InfiniBand QDR4 independent full-duplex channelsUp to 11.2Gbps data rate per channelHot Pluggable850nm VCSEL array transmitterMPO-12 receptacle connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 300m over MM OM3 fiber and 400m over MM OM4 fiberRoHS Compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-IQ-C85-X1D40G850 / 908nm VCSELDuplex BiDi LCOM3 100mOM4 150m0~70°CQSFP+40G-BD-RX 40GBASE-SR2 Ethernet @41.3G40Gbps Data Monitoring Compatible with 40GBASE-SR2 BiDiCompliant with SFF-8436 QSFP+ MSACompliant with IEEE 802.3ba-2010 40GbE XLPPI InterfaceDual wavelength 850/908nm optical interfaceUp to 11.2Gbps data rate per 10G channelBuilt in quad Rx CDRHot PluggableDual Bidi LC connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyRx Sensitivity<-6.5dBm on MMFMaximum power consumption 3.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-IC-C85-X1D40G850 / 908nm VCSELDuplex BiDi LCOM3 100mOM4 150m0~70°CQSFP+ 40G-SRBD, C-Temp 40GBASE-SR2 Ethernet @41.3GData Centers Switch InterconnectServer and Storage Area Network Interconnect Compliant with 40GBASE-SR2 BiDiCompliant with SFF-8436 QSFP+ MSACompliant with IEEE 802.3ba-2010 40GbE XLPPI InterfaceDual wavelength 850 / 908nm VCSEL BiDirectional optical interfaceUp to 11.2Gbps data rate per 10G channelBuilt in quad TX CDR and RX CDRHot PluggableDual Bidi LC connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 100m over OM3 fiber and 150m over MM OM4 fiberMaximum power consumption 3.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I7-C13-02D40GCWDM DFBDuplex LCSM 2km0~70°CQSFP+ 40G-IR4FQFP-I7-C13-02Di40GCWDM DFBDuplex LCSM 2km-40~85°CQSFP+ 40G-IR4, I-Temp 40GBASE-LR4 EthernetOTN OTU3 @43.01G, OTU3e2 @44.58GData Centers Switch InterconnectServer and Storage Area Network Interconnect Compatible with IEEE802.3ba 40GBASE-LR4Compliant to SFF-8436 QSFP+ MSASupports QDR / DDR InfiniBand4CH CWDM MUX / DEMUX designData Rate up to 11.2Gbps per LaneHot PluggableCWDM DFB transmitterDuplex LC connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 2km over SM fiberMaximum Power consumption 3.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I7-C13-10D40GCWDM DFBDuplex LCSM 10km0~70°CQSFP+40G-LR4 COB, C-TempFQFP-I7-C13-10Di40GCWDM DFBDuplex LCSM 10km-40~85°CQSFP+40G-LR4 COB, I-TempFQFP-I7-C13-20D40GCWDM DFBDuplex LCSM 20km0~70°CQSFP+ 40G-LR4 20kmFQFP-I7-C13-20Di40GCWDM DFBDuplex LCSM 20km-40~85°CQSFP+ 40G-LR4 20km, I-Temp 40GBASE-LR4 EthernetOTN OTU3 @43.01G, OTU3e2 @44.58GData Centers Switch InterconnectServer and Storage Area Network Interconnect Compliant with IEEE802.3ba 40GBASE-LR4Compliant to SFF-8436 QSFP+ MSASupports QDR / DDR InfiniBand4CH CWDM MUX / DEMUX designData Rate up to 11.2Gbps per LaneHot PluggableCWDM DFB transmitterDuplex LC connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 10km~20km over SM fiberMaximum Power consumption 3.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I7-C13-40D40GCWDM DFBDuplex LCSM 40km0~70°CQSFP+ 40G-ER4, C-TempFQFP-I7-C13-40Di40GCWDM DFBDuplex LCSM 40km-40~85°CQSFP+ 40G-ER4, I-Temp 40GBASE-ER4 EthernettOTN OTU3 @43.01G, OTU3e2 @44.58GtData Centers Switch InterconnecttServer and Storage Area Network Interconnect Compatible with IEEE802.3bm 40GBASE-ER4Compliant to SFF-8436 QSFP+ MSASupports QDR / DDR InfiniBand4CH CWDM MUX / DEMUX designData Rate up to 11.2Gbps per LaneHot PluggableCWDM DFB transmitterAPD receiverDuplex LC connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 40km over SM fiberMaximum Power consumption 4.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I7-C13-60D40GCWDM EMLDuplex LCSM 60km0~70°CQSFP+40G-ZR4 Lite 60kmFQFP-I7-C13-60Di40GCWDM EMLDuplex LCSM 60km-40~85°CQSFP+40G-ZR4 Lite 60km, I-TempFQFP-I7-L13-80D40GLWDM DFBDuplex LCSM 80km0~70°CQSFP+40G-ZR4, C-TempFQFP-I7-L13-80Di40GLWDM DFBDuplex LCSM 80km-40~85°CQSFP+ 40G-ZR4, I-Temp 40GBASE-ZR4 EthernetOTN OTU3 @43.01G, OTU3e2 @44.58GData Centers Switch InterconnectServer and Storage Area Network Interconnect Compatible with IEEE802.3bm 40GBASE-ER4Compliant to SFF-8436 QSFP+ MSASupports QDR / DDR InfiniBand4CH LWDM MUX / DEMUX designData Rate up to 11.2Gbps per LaneHot PluggableO-Band LWDM DFB transmitterAPD receiverDuplex LC connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 60km~80km over SM fiberMaximum Power consumption 4.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I9-S13-02D40G1310nmMPO/MTPSM 2km0~70°CQSFP+ 40G-PSM4-IR 40Gb EthernetOTN OTU3 @43.01G, OTU3e2 @44.58GBreakout to 4 x 10GBASE-LR EthernetInfiniBand DDR, QDR, SDR interconnectsData Center & StorageDatacom / Telecom Switch & Router Compatible with IEEE802.3ba 40GBASE-LR4Compliant to SFF-8436 QSFP+ MSASupports QDR, DDR & SDR InfiniBand4 independent full-duplex channelsUp to 11.2Gbps data rate per channelHot Pluggable1310nm DFB array transmitterMPO-12 receptacle connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 2km over SM fiberPower consumption < 2.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I9-S13-10D40G1310nmMPO/MTPSM 10km0~70°CQSFP+ 40G-PSM4-LR 40Gb EthernetOTN OTU3 @43.01G, OTU3e2 @44.58GBreakout to 4 x 10GBASE-LR EthernetInfiniBand DDR, QDR, SDR interconnectsData Center & StorageDatacom / Telecom Switch & Router Compatible with IEEE802.3ba 40GBASE-LR4Compliant to SFF-8436 QSFP+ MSASupports QDR, DDR & SDR InfiniBand4 independent full-duplex channelsUp to 11.2Gbps data rate per channelHot Pluggable1310nm DFB array transmitterMPO-12 receptacle connector2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 10km over SM fiberPower consumption < 2.5WRoHS compliant
產品料號資料傳輸率波長連接器傳輸距離操作溫度備註規格書FQFP-I7-S85-X2D40GSWDM VCSELDuplex LCOM3 240mOM4 350mOM5 440m0~70°CQSFP+40G-SWDM4, C-Temp 40GBASE Ethernet over duplex MMFData Centers Switch InterconnectServer and Storage Area Network Interconnect Compatible with IEEE802.3ba 40GBASE EthernetCompliant with SFF-8436 QSFP+ MSACompliant with 40G SWDM4 MSA4CH SWDM MUX / DEMUX designSupports 41.2Gbps aggregate bit rateHot Pluggable4x10Gb/s VCSEL SWDM transmitterDuplex LC connectorXLPPI electrical interface2-wire interface for management and diagnostic monitor compliant with SFF-8436, SFF-8636Single 3.3V power supplyLink distance 240m over OM3 fiber, 350m over OM4 fiber and 440m over OM5 fiberOperating Temperature 0~+70°CMaximum Power consumption 3.5WRoHS compliant