| 詢價單 | 規格 | 特點 | 下載 |
| | | Parameter | Technical indicators | |
|---|
| Size (mm) | 1U 19” : 482.5 (W) x 350 (D) x 44.5 (H) | | Slot | 1-Slot for Management, 3-Slot for Service | | Power Supply | Dual Power Supply 100~240VAC, -48VDC optional | | Power Consumption | <120W | | FAN | 4*40mm FAN | | Enviornment │ Operating Temperature | -10 ~ 60 °C | | Enviornment │ Storage Temperature | -40 ~ 85 °C | | Enviornment │ Relative Humidity | 5 ~ 95 RH% |
| - 1U 19” Rack Compact size
- 1 Slot for Management
- 3 Slots for Service module cards
- Bulti-in Management unit
- Modular design for Power and FAN module
- Hot Pluggable, Easy Replacement
- 1+1 Balanced and Redundancy Power supply,
- AC / DC optional
- Support SNMP-based Network management
- Support CLI, WEB, Telnet and NMS
- Visual Graphic information interface
- Support Entire network topology, elements auto-discovery and generation
- Support Voice alarm, e-mail alerts, SMS alerts, Real-time online remote monitoring
| |
| | | Parameter | Technical indicators | |
|---|
| Size (mm) | 2U 19” : 482.5(W) x 350(D) x 89(H) | | Slot | 1-Slot for Management, 7-Slot for Service | | Power Supply | Dual Power Supply 100~240VAC, -48VDC optional | | Power Consumption | <200W | | FAN | 3*80mm FAN | | Enviornment │ Operating Temperature | -10 ~ 60 °C | | Enviornment │ Storage Temperature | -40 ~ 85 °C | | Enviornment │ Relative Humidity | 5 ~ 95 RH% |
| - 2U 19” Rack Compact size
- 1 Slot for Management
- 7 Slots for Service module cards
- Modular design for Power and FAN module
- Hot Pluggable, Easy Replacement
- 1+1 Balanced and Redundancy Power supply,
- AC / DC optional
- Support SNMP-based Network management
- Support CLI, WEB, Telnet and NMS
- Visual Graphic information interface
- Support Entire network topology, elements auto-discovery and generation
- Support Voice alarm, e-mail alerts, SMS alerts, Real-time online remote monitoring
| |
| | | Parameter | Technical indicators | |
|---|
| Size (mm) | 5U 19” : 482.5(W) x 350(D) x 222.5(H) | | Slot | 1-Slot for Management, 19-Slot for Service | | Power Supply | Dual Power Supply 100~240VAC, -48VDC optional | | Power Consumption | <500W | | FAN | 6*80mm FAN | | Enviornment │ Operating Temperature | -10 ~ 60 °C | | Enviornment │ Storage Temperature | -40 ~ 85 °C | | Enviornment │ Relative Humidity | 5 ~ 95 RH% |
| - 5U 19” Rack Compact size
- 1 Slot for Management
- 19 Slots for Service module cards
- Modular design for Power and FAN module
- Hot Pluggable, Easy Replacement
- 1+1 Balanced and Redundancy Power supply,
- AC / DC optional
- Support SNMP-based Network management
- Support CLI, WEB, Telnet and NMS
- Visual Graphic information interface
- Support Entire network topology, elements auto-discovery and generation
- Support Voice alarm, e-mail alerts, SMS alerts, Real-time online remote monitoring
📣 解鎖短距離傳輸:如何最大化光網路解決方案! 🌟 FICER F520 OTN DWDM 傳輸平台(高密度波分複用光纖骨幹傳輸系統設備)專為解決您的光纖網路挑戰而設計,具有易於使用、安裝、部署和管理的特點。 其主要功能是處理多個光信號。利用波長轉換、複用、解複用、光放大和光色散補償等技術,它可以在有限的光纖資源上傳輸多個高帶寬信號到遠距離目的地。這使得客戶能夠在不部署新電纜的情況下,利用現有的光纖資源實現超長距離傳輸,達到傳統光模組無法實現的帶寬擴展。 主要特點包括高密度集成平台、高度靈活的配置能力和高容量(能夠在不同功能卡下執行各種任務)。適用於城域內或城域網路之間的帶寬擴展、長距離骨幹傳輸和海量數據容量傳輸等場景。 此外,FICER F520 設備提供靈活性,能夠構建經濟高效的光傳輸網絡。非常適合電信運營商、企業、金融機構、公用事業單位、政府機構、廣播公司、教育網絡和內容服務提供商使用。 更多 F520 OTN DWDM 傳輸平台資訊 
| |
| | - Advanced Optical Service Channel (OSC) protocol
- Security
- Alarm Management
- Multiple management mode
- Graphical User Interface (GUI) management
- Multiple front panel ports for management access
- Extensive management features
| |
| | - Metro CWDM / DWDM distance extension
- Long-Haul transmission system
- Wavelength Conversion
- Signal Repeating
- Media Conversion
| - 3R signal regeneration (Reshaping, Retiming, Reamplify)
- Support multiple services and Wide data rate : 1.25Gbps~11.3Gbps
- Hot Swap
- Real-Time DDM
- Support ALS (Automatic Laser Shutdown)
- Support LFP (Link Forward Pass though)
- Ultra-Low latency
- Low power consumption
- Support all F520 Chassis
| |
| | - Metro CWDM / DWDM distance extension
- Long-Haul transmission system
- Wavelength Conversion
- Signal Repeating
- Media Conversion
| - 1R signal regeneration (Reamplify)
- Support multiple services and Wide data rate : 1.25Gbps~28Gbps
- Hot Swap
- Real-Time DDM
- Support ALS (Automatic Laser Shutdown)
- Ultra-Low latency
- Low power consumption
- Support all F520 Chassis
| - |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 1*100G QSFP28
- Line side: 1*100G CFP
- Hot Swap
- Support Line-side GFEC (G.709 RS-FEC), EFEC and SDFEC (depends on CFP-DCO module)
- Support port loopback test
- Dispersion Tolerance up to 40000ps/nm (depends on CFP-DCO module)
- Support adjustable wavelength with CFP-DCO module
- Support adjustable output power with CFP-DCO module
- Support OSNR real-time monitoring with CFPDCO module
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 3*40/100G QSFP28
- Line side: 3*40/100G QSFP28
- Back-to-Back transparent transmission
- Hot Swap
- Real-Time DDM
- Support ALS (Automatic Laser Shutdown)
- Support LFP (Link Forward Pass though)
- Low power consumption
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 1*400G QSFP56-DD
- Line side: 1*400G CFP2
- Support Line-side GFEC (G.709 RS-FEC), EFEC and SDFEC (depends on CFP2-DCO module)
- Dispersion Tolerance up to 40000ps/nm (depends on CFP2-DCO module)
- Support adjustable wavelength with CFP2-DCO module
- Support adjustable output power with CFP2-DCO module
- Support OSNR real-time monitoring with CFP2-DCO module
- Support port Loopback test
- Hot Swap
- Real-Time DDM
- Support ALS (Automatic Laser Shutdown)
- Support all F520 Chassis
| - |
| | - Metro DWDM distance extension
- Long Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 1*40/100G QSFP28
- Line side: 4*10/25G QSFP28
- Back to Back transparent transmission
- Hot Swap
- Real Time DDM
- Support ALS ( Automatic Laser Shutdown )
- Low power consumption
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Long Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 10*10G SFP+
- Line side: 1*100G QSFP28
- Support 10G and 100G Etherenet
- Hot Swap
- Real-Time DDM
- Support ALS (Automatic Laser Shutdown)
- Low power consumption
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 2*100G QSFP28
- Line side: 1*100/200G CFP2
- Hot Swap
- Support Line-side GFEC (G.709 RS-FEC), EFEC and SDFEC (depends on CFP-DCO module)
- Support port loopback test
- Dispersion Tolerance up to 40000ps/nm (depends on CFP2-DCO module)
- Support adjustable wavelength with CFP2-DCO module
- Support adjustable output power with CFP2-DCO module
- Support OSNR real-time monitoring with CFP2-DCO module
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 4*100G QSFP28
- Line side: 1*100/200/400G CFP2
- Support Line-side GFEC (G.709 RS-FEC), EFEC and SDFEC (depends on CFP2-DCO module)
- Support Client-side 100GE RS(528,514) FEC
- Dispersion Tolerance up to 40000ps/nm (depends on CFP2-DCO module)
- Support adjustable wavelength with CFP2-DCO module
- Support adjustable output power with CFP2-DCO module
- Support OSNR real-time monitoring with CFP2-DCO module
- Support port Loopback test
- Hot Swap
- Real-Time DDM
- Support ALS (Automatic Laser Shutdown)
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Signal Repeating
- Media Conversion
- Lambda Conversion
| - Client side: 4*100G QSFP28
- Line side: 1*400G QSFP56-DD
- Support Line-side Multi-Rate 100/200/300/400G (depends on QSFP56-DD DCO module)
- Support Line-side oFEC
- Support Client-side 100GE RS(528,514) FEC
- Dispersion Tolerance up to 20000ps/nm @400G (depends on QSFP56-DD DCO module)
- Support adjustable wavelength with QSFP56-DD DCO module
- Support adjustable output power with QSFP56-DD DCO module
- Support OSNR real-time monitoring with QSFP56-DD DCO modul
- Support port Loopback test
- Hot Swap
- Real-Time DDM
- Support ALS (Automatic Laser Shutdown)
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Single wavelength distance extension
- CATV network system
- Long-Haul transmission system
| - Low noise figure : typical 5dB
- Gain Flattening Filters ( GFF ) assure flat Gain ( <1dB variance ) over the entire amplified band
- Multiple operating modes : AGC, APC, ACC
- High performance transient response control to ensure Power, Gain stable without affecting existing signal
- Support customized saturated Output Power range 13 ~ 24dBm
- Support customized Gain variety range 8 ~ 40dB
- Support Red / Blue port for single-fiber DWDM transmission system
- Support Mid-Stage access for insertion of a DCM or OADM unit without it’s inherent loss.
- Optional OSC management channel for remote management
- Own monitoring port, real-time monitoring optical power and OSNR
- Support SNMP, Web, Console management
- Support 4, 8, 20 slot chassis for different capacity requirement
| |
| | - Metro DWDM distance extension
- Single wavelength distance extension
- CATV network system
- Long-Haul transmission system
| - Low noise figure : typical 5dB
- Gain Flattening Filters (GFF) assure flat Gain (<1dB variance) over the entire amplified band
- Multiple operating modes : AGC, APC, ACC
- High performance transient response control to ensure Power, Gain stable without affecting existing signal
- Support customized saturated Output Power range 13 ~ 24dBm
- Support customized Gain variety range 8 ~ 40dB
- Support Red / Blue port for single-fiber DWDM transmission system
- Optional OSC management channel for remote management
- MON own monitoring port, on-line monitoring optical power and OSNR
- Support SNMP, Web, Console management
- Support 4, 8, 20 slot chassis for different capacity requirement
| |
| | - Ultra Long-Haul transmission system
- Submarine optical transmission system
| - Support the C-Band wavelength range of 1528~1565nm
- Typical Gain 26dB (F520-DRA-BW26)
- Typical Gain 4dB (F520-DRA-FW04)
- Excellent Gain Flatness
- ACC or APC operation mode
- Low Noise Figure Typical 0dB
| - |
| | - O-Band optical signal overall amplification
- 40G / 100G 1310nm signal amplification
| - Support the O-Band wavelength range of 1290~1320nm
- MAX. Output Power 10dBm
- Support up to 160Gbps data rate.
- APC operation mode
- Low Noise, High Gain
- Option 1 and 2 channel of signal amplification
| |
| | - Long-Haul / Metro DWDM system
- DWDM networks/span
| - 100GHz Channel Spacing
- Support up to 16 channels
- Plug and play, no configuration required
- Passive products without power and cooling needs
- High Isolation and Low Insertion Loss
- Stable and Reliable performance
- High integration card package
- Support Monitoring and Express channel
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
| - Channel spacing 100GHz (0.8nm) up to MAX 40
- channels can be multiplexed
- High integration
- Low insertion loss ≤6dB, typical 4.5dB
- High channel isolation
- Adjacent isolation ≥25dB
- Non-adjacent isolation ≥35dB
- Perfect indicator status
- Advanced network management feature : Support SNMP, CLI, WEB approach
- Full graphical management
- Fit F520 1U4S and 2U8S with 5U20S Chassis
- All Chassis support 19" Rack
| |
| | - Metro / Access CWDM system
- CWDM networks
| - Support up to 16 channels
- Plug and play, no configuration required
- Passive products without power and cooling needs
- High Isolation and Low Insertion Loss
- Stable and Reliable performance
- High integration card package
- Support Monitoring and Express channel
| |
| | - High speed transmission system
- Long-haul telecommunication system
- Dispersion limit extension of DWDM system
| - DWDM system dispersion compensation and Broadband low residual dispersion
- G.652 fiber C-Band 100% slope compensation
- Low insertion loss
- Low polarization model dispersion
- Conform to Telcordia GR-2854-CORE standard
- Reliability tested by Telcordia GR-1221-CORE
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Optical Line Protection
| - Reduce interrupt time of communication caused by fiber failure remarkably
- Real-Time fiber power monitoring
- Transparent Data Rate transmission
- Support Automatic and Manual Switching
- 1+1 and 1:1 protection scheme available
- Switching time< 15ms (1+1 scheme)
- Single +3.3V power supply
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Optical Line Protection
| - Reduce interrupt time of communication caused by fiber failure remarkably
- Real-Time fiber power monitoring
- Support Automatic and Manual Switching
- 1+1 protection scheme available
- Work under Red / Blue light single fiber system
- Work with 1x2 Splitter on one side
- Switching time< 20ms
- Support all F520 Chassis
| |
| | - Metro DWDM distance extension
- C-Band DWDM signals amplifying
- CATV network system
- Long-Haul transmission system
| - Fixed 1U Rack package, LC optical port
- Low Noise Figure : typical 5dB, MAX 5.5dB
- Multiple operating modes : AGC, APC, ACC
- High performance transient response control to ensure Power, Gain stable without affecting existing signal
- Support customized saturated Output Power up to +22dBm
- Support customized Gain variety range 8 ~ 35dB
- Optional OSC management channel for remote management
- Support Red / Blue port for the single-fiber DWDM transmission system
- Support Mid-Stage access for the insertion of a DCM or OADM unit without its inherent loss
- MON port for on-line monitoring optical power and OSNR
- Support LCD screen with Panel buttons control
- Support SNMP, Web management
- 1+1 Pluggable Redundancy Power supply, AC / DC optional
| |
| | - Metro DWDM distance extension
- Long-Haul transmission system
- Optical Line Protection
| - Reduce interrupt time of communication caused by fiber failure remarkably
- Real-Time fiber power monitoring
- Transparent Data Rate transmission
- 1+1 and 1:1 protection scheme available
- Switching time< 15ms (1+1 scheme)
- Support Automatic and Manual Switching
- Support LCD screen with Panel buttons control
- Support SNMP, Web management
- 1+1 Pluggable Redundancy Power supply, AC / DC optional
| |
| | - High speed transmission system
- Long-haul telecommunication system
- Dispersion limit extension of DWDM system
| - DWDM system dispersion compensation and Broadband low residual dispersion
- Conform to Telcordia GR-2854-CORE standard
- Reliability tested by Telcordia GR-1221-CORE
| |